{"id":857,"date":"2018-08-28T09:10:36","date_gmt":"2018-08-28T08:10:36","guid":{"rendered":"https:\/\/journals.myesr.org\/eur-radiol\/2018\/08\/28\/whole-body-ct-1-5-msv-detects-osteolytic-lesions\/"},"modified":"2025-09-19T10:28:03","modified_gmt":"2025-09-19T09:28:03","slug":"whole-body-ct-1-5-msv-detects-osteolytic-lesions","status":"publish","type":"post","link":"https:\/\/journals.myesr.org\/eur-radiol\/highlights\/whole-body-ct-1-5-msv-detects-osteolytic-lesions\/","title":{"rendered":"Whole body CT with only 1.5 mSv detects osteolytic lesions"},"content":{"rendered":"<p>Whole body CT with only 1.5 mSv detects osteolytic lesions<br \/>\nVery low-dose CT examinations can be achieved with low kV and tin filtering, reaching a total dose of 1.5 mSv for this whole-body examination. CT can now become a routine tool to detect and follow-up osteolytic lesions with a benefit of time and simplicity as compared to radiographs and MRI.<\/p>\n<p><strong>Key points:<\/strong><\/p>\n<ul>\n<li>Spectral shaping using tin filtration is beneficial for whole-body low-dose CT.<\/li>\n<li>Sn 100 kV yields sufficient image quality for depiction of osteolytic lesions.<\/li>\n<li>Whole-body low-dose CT can be performed with a median dose of 1.5 mSv.<\/li>\n<\/ul>\n<p><strong>Article:<\/strong> <a href=\"https:\/\/link.springer.com\/article\/10.1007\/s00330-017-5243-8\" target=\"_blank\" rel=\"noopener noreferrer\">Whole-body ultra-low dose CT using spectral shaping for detection of osteolytic lesion in multiple myeloma<\/a><\/p>\n<p><strong>Authors:<\/strong> Saravanabavaan Suntharalingam, Christian Mikat, Axel Wetter, Nika Guberina, Ahmed Salem, Philipp Heil, Michael Forsting and Kai Nassenstein<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Whole body CT with only 1.5 mSv detects osteolytic lesions Very low-dose CT examinations can be achieved with low kV and tin filtering, reaching a total dose of 1.5 mSv for this whole-body examination. CT can now become a routine tool to detect and follow-up osteolytic lesions with a benefit of time and simplicity as [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":1889,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","inline_featured_image":false,"footnotes":""},"categories":[7],"tags":[],"class_list":["post-857","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-highlights"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.2 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Whole body CT with only 1.5 mSv detects osteolytic lesions - European Radiology<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/journals.myesr.org\/eur-radiol\/highlights\/whole-body-ct-1-5-msv-detects-osteolytic-lesions\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Whole body CT with only 1.5 mSv detects osteolytic lesions - European Radiology\" \/>\n<meta property=\"og:description\" content=\"Whole body CT with only 1.5 mSv detects osteolytic lesions Very low-dose CT examinations can be achieved with low kV and tin filtering, reaching a total dose of 1.5 mSv for this whole-body examination. CT can now become a routine tool to detect and follow-up osteolytic lesions with a benefit of time and simplicity as [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/journals.myesr.org\/eur-radiol\/highlights\/whole-body-ct-1-5-msv-detects-osteolytic-lesions\/\" \/>\n<meta property=\"og:site_name\" content=\"European Radiology\" \/>\n<meta property=\"article:published_time\" content=\"2018-08-28T08:10:36+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-09-19T09:28:03+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/journals.myesr.org\/eur-radiol\/wp-content\/uploads\/sites\/2\/2025\/09\/Suntharalingam_et-al_2A.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"269\" \/>\n\t<meta property=\"og:image:height\" content=\"892\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"editor\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"editor\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/journals.myesr.org\/eur-radiol\/highlights\/whole-body-ct-1-5-msv-detects-osteolytic-lesions\/\",\"url\":\"https:\/\/journals.myesr.org\/eur-radiol\/highlights\/whole-body-ct-1-5-msv-detects-osteolytic-lesions\/\",\"name\":\"Whole body CT with only 1.5 mSv detects osteolytic lesions - European Radiology\",\"isPartOf\":{\"@id\":\"https:\/\/journals.myesr.org\/eur-radiol\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/journals.myesr.org\/eur-radiol\/highlights\/whole-body-ct-1-5-msv-detects-osteolytic-lesions\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/journals.myesr.org\/eur-radiol\/highlights\/whole-body-ct-1-5-msv-detects-osteolytic-lesions\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/journals.myesr.org\/eur-radiol\/wp-content\/uploads\/sites\/2\/2025\/09\/Suntharalingam_et-al_2A.jpg\",\"datePublished\":\"2018-08-28T08:10:36+00:00\",\"dateModified\":\"2025-09-19T09:28:03+00:00\",\"author\":{\"@id\":\"https:\/\/journals.myesr.org\/eur-radiol\/#\/schema\/person\/6b90d4d1c826ba40890f732bdc096ff3\"},\"breadcrumb\":{\"@id\":\"https:\/\/journals.myesr.org\/eur-radiol\/highlights\/whole-body-ct-1-5-msv-detects-osteolytic-lesions\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/journals.myesr.org\/eur-radiol\/highlights\/whole-body-ct-1-5-msv-detects-osteolytic-lesions\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/journals.myesr.org\/eur-radiol\/highlights\/whole-body-ct-1-5-msv-detects-osteolytic-lesions\/#primaryimage\",\"url\":\"https:\/\/journals.myesr.org\/eur-radiol\/wp-content\/uploads\/sites\/2\/2025\/09\/Suntharalingam_et-al_2A.jpg\",\"contentUrl\":\"https:\/\/journals.myesr.org\/eur-radiol\/wp-content\/uploads\/sites\/2\/2025\/09\/Suntharalingam_et-al_2A.jpg\",\"width\":269,\"height\":892},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/journals.myesr.org\/eur-radiol\/highlights\/whole-body-ct-1-5-msv-detects-osteolytic-lesions\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/journals.myesr.org\/eur-radiol\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Whole body CT with only 1.5 mSv detects osteolytic lesions\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/journals.myesr.org\/eur-radiol\/#website\",\"url\":\"https:\/\/journals.myesr.org\/eur-radiol\/\",\"name\":\"European Radiology\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/journals.myesr.org\/eur-radiol\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/journals.myesr.org\/eur-radiol\/#\/schema\/person\/6b90d4d1c826ba40890f732bdc096ff3\",\"name\":\"editor\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/journals.myesr.org\/eur-radiol\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/14699bc4a68dcfa7330767f49cf436219cc6a600e0625083b22c8baadc93ef35?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/14699bc4a68dcfa7330767f49cf436219cc6a600e0625083b22c8baadc93ef35?s=96&d=mm&r=g\",\"caption\":\"editor\"},\"url\":\"https:\/\/journals.myesr.org\/eur-radiol\/author\/editor\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Whole body CT with only 1.5 mSv detects osteolytic lesions - European Radiology","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/journals.myesr.org\/eur-radiol\/highlights\/whole-body-ct-1-5-msv-detects-osteolytic-lesions\/","og_locale":"en_GB","og_type":"article","og_title":"Whole body CT with only 1.5 mSv detects osteolytic lesions - European Radiology","og_description":"Whole body CT with only 1.5 mSv detects osteolytic lesions Very low-dose CT examinations can be achieved with low kV and tin filtering, reaching a total dose of 1.5 mSv for this whole-body examination. CT can now become a routine tool to detect and follow-up osteolytic lesions with a benefit of time and simplicity as [&hellip;]","og_url":"https:\/\/journals.myesr.org\/eur-radiol\/highlights\/whole-body-ct-1-5-msv-detects-osteolytic-lesions\/","og_site_name":"European Radiology","article_published_time":"2018-08-28T08:10:36+00:00","article_modified_time":"2025-09-19T09:28:03+00:00","og_image":[{"width":269,"height":892,"url":"https:\/\/journals.myesr.org\/eur-radiol\/wp-content\/uploads\/sites\/2\/2025\/09\/Suntharalingam_et-al_2A.jpg","type":"image\/jpeg"}],"author":"editor","twitter_card":"summary_large_image","twitter_misc":{"Written by":"editor","Estimated reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/journals.myesr.org\/eur-radiol\/highlights\/whole-body-ct-1-5-msv-detects-osteolytic-lesions\/","url":"https:\/\/journals.myesr.org\/eur-radiol\/highlights\/whole-body-ct-1-5-msv-detects-osteolytic-lesions\/","name":"Whole body CT with only 1.5 mSv detects osteolytic lesions - European Radiology","isPartOf":{"@id":"https:\/\/journals.myesr.org\/eur-radiol\/#website"},"primaryImageOfPage":{"@id":"https:\/\/journals.myesr.org\/eur-radiol\/highlights\/whole-body-ct-1-5-msv-detects-osteolytic-lesions\/#primaryimage"},"image":{"@id":"https:\/\/journals.myesr.org\/eur-radiol\/highlights\/whole-body-ct-1-5-msv-detects-osteolytic-lesions\/#primaryimage"},"thumbnailUrl":"https:\/\/journals.myesr.org\/eur-radiol\/wp-content\/uploads\/sites\/2\/2025\/09\/Suntharalingam_et-al_2A.jpg","datePublished":"2018-08-28T08:10:36+00:00","dateModified":"2025-09-19T09:28:03+00:00","author":{"@id":"https:\/\/journals.myesr.org\/eur-radiol\/#\/schema\/person\/6b90d4d1c826ba40890f732bdc096ff3"},"breadcrumb":{"@id":"https:\/\/journals.myesr.org\/eur-radiol\/highlights\/whole-body-ct-1-5-msv-detects-osteolytic-lesions\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/journals.myesr.org\/eur-radiol\/highlights\/whole-body-ct-1-5-msv-detects-osteolytic-lesions\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/journals.myesr.org\/eur-radiol\/highlights\/whole-body-ct-1-5-msv-detects-osteolytic-lesions\/#primaryimage","url":"https:\/\/journals.myesr.org\/eur-radiol\/wp-content\/uploads\/sites\/2\/2025\/09\/Suntharalingam_et-al_2A.jpg","contentUrl":"https:\/\/journals.myesr.org\/eur-radiol\/wp-content\/uploads\/sites\/2\/2025\/09\/Suntharalingam_et-al_2A.jpg","width":269,"height":892},{"@type":"BreadcrumbList","@id":"https:\/\/journals.myesr.org\/eur-radiol\/highlights\/whole-body-ct-1-5-msv-detects-osteolytic-lesions\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/journals.myesr.org\/eur-radiol\/"},{"@type":"ListItem","position":2,"name":"Whole body CT with only 1.5 mSv detects osteolytic lesions"}]},{"@type":"WebSite","@id":"https:\/\/journals.myesr.org\/eur-radiol\/#website","url":"https:\/\/journals.myesr.org\/eur-radiol\/","name":"European Radiology","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/journals.myesr.org\/eur-radiol\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/journals.myesr.org\/eur-radiol\/#\/schema\/person\/6b90d4d1c826ba40890f732bdc096ff3","name":"editor","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/journals.myesr.org\/eur-radiol\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/14699bc4a68dcfa7330767f49cf436219cc6a600e0625083b22c8baadc93ef35?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/14699bc4a68dcfa7330767f49cf436219cc6a600e0625083b22c8baadc93ef35?s=96&d=mm&r=g","caption":"editor"},"url":"https:\/\/journals.myesr.org\/eur-radiol\/author\/editor\/"}]}},"_links":{"self":[{"href":"https:\/\/journals.myesr.org\/eur-radiol\/wp-json\/wp\/v2\/posts\/857","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/journals.myesr.org\/eur-radiol\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/journals.myesr.org\/eur-radiol\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/journals.myesr.org\/eur-radiol\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/journals.myesr.org\/eur-radiol\/wp-json\/wp\/v2\/comments?post=857"}],"version-history":[{"count":1,"href":"https:\/\/journals.myesr.org\/eur-radiol\/wp-json\/wp\/v2\/posts\/857\/revisions"}],"predecessor-version":[{"id":1557,"href":"https:\/\/journals.myesr.org\/eur-radiol\/wp-json\/wp\/v2\/posts\/857\/revisions\/1557"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/journals.myesr.org\/eur-radiol\/wp-json\/wp\/v2\/media\/1889"}],"wp:attachment":[{"href":"https:\/\/journals.myesr.org\/eur-radiol\/wp-json\/wp\/v2\/media?parent=857"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/journals.myesr.org\/eur-radiol\/wp-json\/wp\/v2\/categories?post=857"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/journals.myesr.org\/eur-radiol\/wp-json\/wp\/v2\/tags?post=857"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}